Houston, TX Office Equipment - Apollo Office Systems

Raritan

View as Grid List
Sort by
Display per page

Raritan PX3-5941V-V2 power distribution unit (PDU) 18 AC outlet(s) 0U Black

5706592
Raritan PX3-5941V-V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 18 AC outlet(s), AC outlet types: C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 208 V, Maximum current: 100 A, AC input frequency: 50 - 60 Hz

Raritan PX3-4782V-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

6367056
Raritan PX3-4782V-V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 400 V, Maximum current: 63 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5747V-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

5946880
Raritan PX3-5747V-V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60309. Cable length: 118.1" (3 m), Certification: UL. Monitoring: Current, Power, Voltage, Supported network protocols: TFTP, DHCP, SSH(CLI). Nominal input voltage: 415 V, Maximum current: 60 A, Load capacity: 34500 VA

Raritan PX3-5747I2U-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

5893723
Raritan PX3-5747I2U-V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 415 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5747T-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

5523249
Raritan PX3-5747T-V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60309. Cable length: 118.1" (3 m). Monitoring: Current, Power, Voltage, Supported network protocols: TFTP, DHCP, SSH(CLI). Nominal input voltage: 415 V, Maximum current: 60 A, Load capacity: 34500 VA

Raritan PX3-5747U-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

5523250
Raritan PX3-5747U-V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 415 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz