Lantronix EDS-MD 8-Port serial server RS-232

Lantronix EDS-MD 8-Port. Cabling technology: 10/100/1000Base-T(X). Input voltage: 100 - 240 V. Security algorithms: 128-bit AES, 3DES, MD5, SHA-1, SSH-2, SSL/TLS. Weight: 28.9 oz (820 g), Dimensions (WxDxH): 7.48 x 8.27 x 2.36" (190 x 210 x 60 mm). Built-in processor: ARM 11, Processor frequency: 600 MHz
SKU: 6761447
Manufacturer part number: EDSOR08P-01
GTIN: 0783384234871
Next Generation Multi-Port Medical Device Server Specifically designed for the medical industry, the UL and IEC-60601 compliant EDS-MDTM provides mission-critical device connectivity, allowing remote access and management of virtually any electronic or medical device. EDS-MD boasts 4, 8 or 16 individually isolated RS-232 serial ports with a Gigabit (10/100/1000Mpbs) network interface. Going above and beyond the IEC-60601 requirement, EDS-MD provides galvanic isolation on all ports to ensure the highest levels of safety. If a grounding problem occurs, the operation of EDS-MD or other connected devices will not be affected. With Lantronix’ proprietary Secure Com Port Redirector virtualization software, existing serial port applications can work with EDS-MD without any code modifications. Virtual COM ports can be mapped to EDS-MD and encrypted at both ends of the communication, allowing the transport of sensitive information to and from remote device servers over the Internet with the highest level of security. Set up and configuration of EDS-MD is simple with industry-standard management tools including Web, CLI and XML.
Next Generation Multi-Port Medical Device Server Specifically designed for the medical industry, the UL and IEC-60601 compliant EDS-MDTM provides mission-critical device connectivity, allowing remote access and management of virtually any electronic or medical device. EDS-MD boasts 4, 8 or 16 individually isolated RS-232 serial ports with a Gigabit (10/100/1000Mpbs) network interface. Going above and beyond the IEC-60601 requirement, EDS-MD provides galvanic isolation on all ports to ensure the highest levels of safety. If a grounding problem occurs, the operation of EDS-MD or other connected devices will not be affected. With Lantronix’ proprietary Secure Com Port Redirector virtualization software, existing serial port applications can work with EDS-MD without any code modifications. Virtual COM ports can be mapped to EDS-MD and encrypted at both ends of the communication, allowing the transport of sensitive information to and from remote device servers over the Internet with the highest level of security. Set up and configuration of EDS-MD is simple with industry-standard management tools including Web, CLI and XML.
Products specifications
Attribute nameAttribute value
Built-in processorARM 11
Weight28.9 oz
Technical details
Baud rate921 Kbit/s
Isolation1.5 kV
Serial interface typeRS-232
Electrostatic Discharge (ESD) protection15 kV
Flow control supportY
Ports & interfaces
USB 2.0 ports quantity2
Serial ports quantity8
Design
CertificationFCC part 15 Subpart B EN 60601-1-2: 2007 ICES-003 CISPR 22:2005 + A1: 2005 + A2: 2006 ITE CISPR 11:2003 + A1: 2004 + A2: 2006 VCCI V-3/2010.04 AS/NZS CISPR 22: 2009 EN 55022: 2006 + A1: 2007 EN61000-3-2: 2006 + A1: 2009 + A2: 2009 EN61000-3-3: 2008 Reach RoHS EN55024 1998 + A1: 2001 + A2: 2003 EN60601-1-2: 2007 EN61000-4-2: 2009 EN61000-4-3: 2006 + A1: 2008 EN61000-4-4: 2004 + A1: 2010 EN61000-4-5: 2006 EN61000-4-6: 2009 EN61000-4-8: 1994 + A1: 2001 EN61000-4-11: 2004
Operational conditions
Operating temperature (T-T)0 - 55 °C
Storage temperature (T-T)-30 - 80 °C
Operating relative humidity (H-H)20 - 90 %
Power
Input voltage100 - 240 V
Weight & dimensions
Dimensions (WxDxH)7.48 x 8.27 x 2.36"
Features
SafetyUL 60950-1, UL 60601-1, CAN/CSA-C22.2; No. 60950-1-07, CAN/CSA C22.2; No. 601.1: 1990, IEC 60601-1: 1998, EN60601-1: 1990, JIS T 0601-1:1999
LED indicatorsY
Other features
Power LEDY
Performance
Networking standardsIEEE 802.3, IEEE 802.3ab, IEEE 802.3u, IEEE 802.3x
Cabling technology10/100/1000Base-T(X)
Processor frequency600 MHz
Network
Ethernet LAN data rates10,100,1000 Mbit/s
Wi-FiN
System requirements
Windows operating systems supportedY
Memory
RAM capacity256 MB
Flash memory8 MB
Security
Security algorithms128-bit AES, 3DES, MD5, SHA-1, SSH-2, SSL/TLS
Protocols
Management protocolsTelnet, SSH, SSL, FTP
Indication
Link/Act LEDY