Raritan PX3-5905I3V-V2 power distribution unit (PDU) 36 AC outlet(s) 0U Black

Raritan PX3-5905I3V-V2. PDU types: Metered, Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60309. Cable length: 118.1" (3 m), Security algorithms: SNMPv2, SNMPv3, Certification: IP67. Monitoring: Humidity, Temperature. Nominal input voltage: 190 - 208 V, Maximum current: 60 A, AC input frequency: 50/60 Hz
Manufacturers: Raritan , RARITAN, INC
SKU: 5515800
Manufacturer part number: PX3-5905I3V-V2
$4,129.00
Tender Text/Bid Submittal Text

Monitored and switched rack power distribution unit (0U [vertical], 17.3kVA, 36 outlets). INPUT: 208v (3-phase DELTA), 60a - IEC 60309 3P+N+E 9h 60A plug (4P5W); OUTPUT: 24@ C13, 12@ C19 outlets; on 6@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 59mm x 80mm x 1981mm (2.3in x 3.1in x 78.0in). Max Weight TBD. Maximum ambient temperature 60C at full load.

Tender Text/Bid Submittal Text

Monitored and switched rack power distribution unit (0U [vertical], 17.3kVA, 36 outlets). INPUT: 208v (3-phase DELTA), 60a - IEC 60309 3P+N+E 9h 60A plug (4P5W); OUTPUT: 24@ C13, 12@ C19 outlets; on 6@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 59mm x 80mm x 1981mm (2.3in x 3.1in x 78.0in). Max Weight TBD. Maximum ambient temperature 60C at full load.

Products specifications

Attribute name Attribute value
Width 2.32"
Depth 3.15"
Height 78"
Weight 29.3 lbs
Mounting Vertical
Display LCD
Cable Length 118.1"
Type Three-phase
Load Capacity 17300 VA
Monitoring Humidity, Temperature
Daisy chain Yes
Circuit breaker Yes
Compliance certificates Federal Communications Commission (FCC), ICES, RoHS
Technical details
Product color Black
Packaging data
Package width 15"
Package depth 5.51"
Package height 90.4"
Package weight 37 lbs
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
AC outlet types C13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports 2
USB ports quantity 3
Power plug IEC 60309
Design
Certification IP67
PDU types Metered, Monitored, Switched
Operational conditions
Operating altitude 0 - 118110.2"
Power
Maximum current 60 A
Nominal input voltage 190 - 208 V
AC input frequency 50/60 Hz
Power protection features Over current, Overload
Features
Rack capacity 0U
LED indicators Yes
Other features
Nominal output voltage 190 - 208 V
Performance
Reset button Yes
Security
Security algorithms SNMPv2, SNMPv3
/* Added for Digitol */ /* End Added for Digitol */