Raritan PX3-1905-N1V2 power distribution unit (PDU) 36 AC outlet(s) 0U Black

Raritan PX3-1905-N1V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60309. Cable length: 118.1" (3 m). Nominal input voltage: 208 V, Maximum current: 60 A, Load capacity: 17300 VA. Width: 1.77" (45 mm), Depth: 3.15" (80 mm), Height: 70.1" (1780 mm)
Manufacturers: Raritan , RARITAN, INC
SKU: 5730271
Manufacturer part number: PX3-1905-N1V2
$2,387.00
Monitored rack power distribution unit (0U [vertical], 17.3kVA, 36 outlets). INPUT: 208v (3-phase DELTA), 60a - IEC 60309 3P+E 9h 60A plug (3P4W); OUTPUT: 24@ C13, 12@ C19 outlets; on 6@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Breaker metering and alarming (0V detection). Max Dimensions 45mm x 80mm x 1780mm (1.8in x 3.1in x 70.1in). Max Weight 13 kg. Maximum ambient temperature 60C at full load.
Monitored rack power distribution unit (0U [vertical], 17.3kVA, 36 outlets). INPUT: 208v (3-phase DELTA), 60a - IEC 60309 3P+E 9h 60A plug (3P4W); OUTPUT: 24@ C13, 12@ C19 outlets; on 6@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Breaker metering and alarming (0V detection). Max Dimensions 45mm x 80mm x 1780mm (1.8in x 3.1in x 70.1in). Max Weight 13 kg. Maximum ambient temperature 60C at full load.

Products specifications

Attribute name Attribute value
Load Capacity 17300 VA
Width 1.77"
Depth 3.15"
Height 70.1"
Weight 28.7 lbs
Mounting Vertical
Cable Length 118.1"
Type Three-phase
Number of phases 3
Warranty period 2 year(s)
Technical details
Product color Black
Packaging data
Package height 70.1"
Package weight 37.5 lbs
Package width 16.3"
Package depth 7.76"
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
AC outlet types C13 coupler, C19 coupler
Power plug IEC 60309
Design
PDU types Monitored
Operational conditions
Operating altitude 0 - 71653.5"
Operating temperature (T-T) 0 - 60 °C
Operating relative humidity (H-H) 0 - 85 %
Power
Maximum current 60 A
Nominal input voltage 208 V
Features
Rack capacity 0U
/* Added for Digitol */ /* End Added for Digitol */