Tripp Lite SU3000RTXLCD2UN uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 2700 W 9 AC outlet(s)

Tripp Lite SU3000RTXLCD2UN. UPS topology: Double-conversion (Online), Output power capacity: 3 kVA, Output power: 2700 W. AC outlet types: NEMA 5-15R, NEMA 5–20R, NEMA L5-30R, Power plug: NEMA L5-30P, AC outlets quantity: 9 AC outlet(s). Typical backup time at full load: 4.1 min, Typical backup time at half load: 11.3 min. Form factor: Rackmount/Tower, Product color: Black, Housing material: Steel. Width: 17.3" (439.4 mm), Depth: 25.5" (647.7 mm), Height: 3.4" (86.4 mm)
Manufacturer: Tripp Lite
SKU: 5810590
Manufacturer part number: SU3000RTXLCD2UN
GTIN: 0037332253552
Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 100/110/120/127V 50/60 Hz UPS system with IGBT technology maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery mode in on-line double-conversion mode, the SmartOnline® SU3000RTXLCD2UN double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. Individually Controllable Load Banks Let You Access and Control Outlets Remotely Four NEMA 5-15R outlets and four 5-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. In addition to those outlets, this UPS provides one NEMA L5-30R outlet for powering critical components. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 11.3 minutes of support at half load (1350W) and 4.1 minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports external battery packs, such as Tripp Lite’s BP72V15-2U (sold separately). The intelligent battery management system with temperature-compensated charging extends battery life. Optional Economy Mode Helps You Save Money and Protect the Environment A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality, which helps you save on energy costs. Automatically Turns Back On After Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD features detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options. LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, ECO mode operation, bypass mode operation and AC output status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite’s free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included. WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control The SU3000RTXLCD2UN includes the Java-free HTML5-based WEBCARDLX that enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. WEBCARDLX allows you to use the Auto Probe feature, which can prevent costly service calls by automatically rebooting non-responsive network devices. Versatile Installation Options Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM (sold separately) for 2-post rack mounting or the optional 2-9USTAND (sold separately) for mounting in an upright tower position. The 10-foot power cord with NEMA L5-30P plug connects to any compatible AC outlet.
Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 100/110/120/127V 50/60 Hz UPS system with IGBT technology maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery mode in on-line double-conversion mode, the SmartOnline® SU3000RTXLCD2UN double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. Individually Controllable Load Banks Let You Access and Control Outlets Remotely Four NEMA 5-15R outlets and four 5-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. In addition to those outlets, this UPS provides one NEMA L5-30R outlet for powering critical components. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 11.3 minutes of support at half load (1350W) and 4.1 minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports external battery packs, such as Tripp Lite’s BP72V15-2U (sold separately). The intelligent battery management system with temperature-compensated charging extends battery life. Optional Economy Mode Helps You Save Money and Protect the Environment A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality, which helps you save on energy costs. Automatically Turns Back On After Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD features detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options. LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, ECO mode operation, bypass mode operation and AC output status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite’s free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included. WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control The SU3000RTXLCD2UN includes the Java-free HTML5-based WEBCARDLX that enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. WEBCARDLX allows you to use the Auto Probe feature, which can prevent costly service calls by automatically rebooting non-responsive network devices. Versatile Installation Options Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM (sold separately) for 2-post rack mounting or the optional 2-9USTAND (sold separately) for mounting in an upright tower position. The 10-foot power cord with NEMA L5-30P plug connects to any compatible AC outlet.
Products specifications
Attribute nameAttribute value
Country of OriginChina
Width17.3"
Depth25.5"
Height3.4"
Weight70.5 lbs
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Cable Length122"
Display TypeLCD
Power factor0.9
UPS topologyDouble-conversion (Online)
Output frequency50/60 Hz
Rack mount kitY
Output voltage regulation2 %
Number of input phases1
EMI/RFI noise filteringY
Cold startY
Crest factor3:1
Emergency Power Off (EPO) connectorY
Technical details
Product colorBlack
Sustainability certificatesRoHS
Packaging data
Package depth39.5"
Package width24.1"
Package height9.1"
Package weight91.9 lbs
Ports & interfaces
AC outlet typesNEMA 5-15R,NEMA 5–20R,NEMA L5-30R
AC outlets quantity9 AC outlet(s)
Ethernet LAN (RJ-45) ports1
RS-232 ports1
USB 2.0 ports quantity3
Power plugNEMA L5-30P
USB portY
Design
CertificationFCC Part 15 Category A (EMI), CSA (Canada), NOM (Mexico), UL1778 (USA)
Form factorRackmount/Tower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Power
Output power capacity3 kVA
Power protection featuresOver voltage, Under voltage
Features
Input operation voltage (max)127 V
Output operation voltage (max)127 V
Rack capacity2U
Cooling typeActive
LED indicatorsY
Built-in fanY
Output power2700 W
Noise level50 dB
Audible alarm(s)Y
Surge energy rating570 J
Input operation voltage (min)100 V
Output operation voltage (min)100 V
WaveformPure sine
Audible alarm modesAlarm when on battery, Fault, Low battery alarm, Overload alarm
Packaging content
ManualY
Cables includedRS-232, USB cable
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load4.1 min
Typical backup time at half load11.3 min
Hot-swap batteryY
Product tags
  • (82310)