Tripp Lite PDUMNV32HV2LX power distribution unit (PDU) 42 AC outlet(s) 0U Black

Tripp Lite PDUMNV32HV2LX. PDU types: Monitored, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC309. Cable length: 118.1" (3 m), Certification: IEC60950-1, TAA. Management platform: Web, SNMP, Telnet. Nominal input voltage: 200-240 V, Maximum current: 32 A, Nominal output voltage: 200-240 V
Manufacturer: Tripp Lite
SKU: 5070548
Manufacturer part number: PDUMNV32HV2LX
GTIN: 0037332204899
The PDUMNV32HV2LX 7.7kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-ft. (3.05 m) cord with IEC 309 32A Blue (2P+E) plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

 

  • 7.7kW 200-240V single-phase monitored 0U PDU
  • 42 outlets—36 C13, 6 C19—with plug-lock insert sleeves
  • Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Digital ammeter for on-site load monitoring in real time
  • IEC 309 32A Blue (2P+E) input with 10-ft. (3.05 m) AC power cord
The PDUMNV32HV2LX 7.7kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-ft. (3.05 m) cord with IEC 309 32A Blue (2P+E) plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

 

  • 7.7kW 200-240V single-phase monitored 0U PDU
  • 42 outlets—36 C13, 6 C19—with plug-lock insert sleeves
  • Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Digital ammeter for on-site load monitoring in real time
  • IEC 309 32A Blue (2P+E) input with 10-ft. (3.05 m) AC power cord
Products specifications
Attribute nameAttribute value
Depth2.65"
Height69.9"
Country of OriginTaiwan
Width2.2"
Weight9.7 lbs
MountingVertical
DisplayLCD
Cable Length118.1"
Compliance certificatesRoHS
Technical details
Management platformWeb, SNMP, Telnet
Product colorBlack
Sustainability certificatesRoHS
Packaging data
Package depth73"
Package width6.4"
Package height5.2"
Package weight14.7 lbs
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Design
CertificationIEC60950-1, TAA
PDU typesMonitored
Operational conditions
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)0 - 95 %
Power
Maximum current32 A
Nominal input voltage200-240 V
Power protection featuresOverload
Weight & dimensions
Dimensions (WxDxH)2.2 x 2.64 x 70"
Features
Rack capacity0U
LED indicatorsYes
Other features
Output connections36 x C13 & 6 x C19
Package dimensions (WxDxH)6.61 x 5.39 x 73.3"
Nominal output voltage200-240 V
Logistics data
Quantity per master (outer) case1 pc(s)
Product tags