Tripp Lite PDUMNV20HV2LX power distribution unit (PDU) 20 AC outlet(s) 0U Black

Tripp Lite PDUMNV20HV2LX. PDU types: Monitored, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 20 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-20P. Cable length: 120.1" (3.05 m). Monitoring: Current, Power, Supported network protocols: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 208-230 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz
Manufacturer: Tripp Lite
SKU: 5070547
Manufacturer part number: PDUMNV20HV2LX
GTIN: 0037332205346
The PDUMNV20HV2LX 3.7kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

Recommended for your IT or industrial application, the 0U PDU features 20 outlets (18 C13 and 2 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. The C20 inlet is compatible with a wide variety of user-supplied power cords for connecting to an AC source, generator or protected UPS. A detachable 10-ft. (3.05 m) cord with NEMA L6-20P plug is included.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor the total connected load in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.

 

  • 3.3/3.7kW 208/230V single-phase monitored 90cm 0U PDU
  • 20 outlets—18 C13, 2 C19—with plug-lock insert sleeves
  • Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Digital ammeter for on-site load monitoring in real time
  • C20 inlet input with detachable 10-ft. (3.05 m) NEMA L6-20P power cord
The PDUMNV20HV2LX 3.7kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

Recommended for your IT or industrial application, the 0U PDU features 20 outlets (18 C13 and 2 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. The C20 inlet is compatible with a wide variety of user-supplied power cords for connecting to an AC source, generator or protected UPS. A detachable 10-ft. (3.05 m) cord with NEMA L6-20P plug is included.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor the total connected load in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.

 

  • 3.3/3.7kW 208/230V single-phase monitored 90cm 0U PDU
  • 20 outlets—18 C13, 2 C19—with plug-lock insert sleeves
  • Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Digital ammeter for on-site load monitoring in real time
  • C20 inlet input with detachable 10-ft. (3.05 m) NEMA L6-20P power cord
Products specifications
Attribute nameAttribute value
Height35.5"
MonitoringCurrent, Power
Country of OriginTaiwan
Width2.2"
Depth1.85"
Weight6.5 lbs
MountingVertical
Cable Length120.1"
TypeSingle-phase
Master AC outlets quantity18
Slave AC outlets quantity2
Compliance certificatesRoHS
Technical details
Product colorBlack
Sustainability certificatesRoHS
Packaging data
Package height42"
Package width6.2"
Package depth4.5"
Package weight11.5 lbs
Ports & interfaces
AC outlets quantity20 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugNEMA L6-20P
Design
PDU typesMonitored
Operational conditions
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)5 - 95 %
Operating altitude0 - 118110.2"
Power
Nominal input voltage208-230 V
Maximum current20 A
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)2.2 x 1.85 x 35.5"
Features
Rack capacity0U
LED indicatorsYes
On/off switchYes
Other features
Nominal output voltage208-230 V
Package dimensions (WxDxH)6.18 x 4.49 x 42"
Packaging content
Cables includedAC
ManualYes
Logistics data
Quantity per master (outer) case1 pc(s)
Protocols
Supported network protocolsIPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP