Tripp Lite PDUBHV101U power distribution unit (PDU) 6 AC outlet(s) 1U Black

Tripp Lite PDUBHV101U. Rack capacity: 1U, Type: Single-phase, Mounting: Horizontal. AC outlets quantity: 6 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler. Nominal input voltage: 200 - 240 V, Maximum current: 10 A, Output voltage: 200 - 240 V. Width: 17.2" (437.9 mm), Depth: 3.94" (100.1 mm), Height: 1.73" (43.9 mm). Package weight: 6.11 lbs (2.77 kg), Package width: 8" (203.2 mm), Package depth: 21.3" (541 mm)
Manufacturer: Tripp Lite
SKU: 6196754
Manufacturer part number: PDUBHV101U
GTIN: 0037332253095
Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200–250V 10A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance. Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation The PDUBHV101U features two C14 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C13-to-C14 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the six C13 outlets will continue to operate without interruption. Optional ECO Switching Feature Enables Cost-Cutting Power Savings By enabling the ECO power saving feature, you can power off a single bank of five controlled C13 outlets all at once when the device connected to the master C13 outlet is powered off or goes into a low-power consumption mode. Mounts into 1U of Rack Space or on a Wall Use the included mounting hardware to install the PDUBHV101U’s all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.

 

  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C14 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 1U of rack space or onto wall using included mounting hardware
Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200–250V 10A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance. Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation The PDUBHV101U features two C14 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C13-to-C14 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the six C13 outlets will continue to operate without interruption. Optional ECO Switching Feature Enables Cost-Cutting Power Savings By enabling the ECO power saving feature, you can power off a single bank of five controlled C13 outlets all at once when the device connected to the master C13 outlet is powered off or goes into a low-power consumption mode. Mounts into 1U of Rack Space or on a Wall Use the included mounting hardware to install the PDUBHV101U’s all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.

 

  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C14 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 1U of rack space or onto wall using included mounting hardware
Products specifications
Attribute nameAttribute value
Master (outer) case GTIN (EAN/UPC)10037332253092
Master (outer) case length21.7"
Country of OriginChina
Width17.2"
Depth3.94"
Height1.73"
Weight4.43 lbs
MountingHorizontal
Housing MaterialMetal
TypeSingle-phase
Master (outer) case weight27.6 lbs
Master (outer) case width16.6"
Master (outer) case height11.8"
Technical details
Product colorBlack
Sustainability certificatesCE, RoHS
Sustainability complianceY
Packaging data
Package depth21.3"
Package weight6.11 lbs
Package width8"
Package height5.2"
Ports & interfaces
AC outlets quantity6 AC outlet(s)
AC outlet typesC13 coupler
Power plugC14 coupler
Operational conditions
Storage temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Storage relative humidity (H-H)0 - 90 %
Operating altitude0 - 118110.2"
Power
Maximum power2400 W
Maximum current10 A
Nominal input voltage200 - 240 V
Features
Rack capacity1U
LED indicatorsY
Output voltage200 - 240 V
Logistics data
Quantity per master (outer) case4 pc(s)