Tripp Lite PDU3EVN6G60C power distribution unit (PDU) 36 AC outlet(s) 0U Black, Gray

Tripp Lite PDU3EVN6G60C. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC309. Cable length: 70.9" (1.8 m), Security algorithms: SNMP, Certification: UL 60950-1:2007 R10.14, CAN/CSA-C22.0 No 60950-1-07-A1:2009 A2:2014, NOM, TAA. Nominal input voltage: 208; 240 V, Maximum current: 45 A, AC input frequency: 50 - 60 Hz. Width: 2.17" (55.1 mm), Depth: 2.49" (63.2 mm), Height: 70" (1778 mm)
Manufacturer: Tripp Lite
SKU: 5205769
Manufacturer part number: PDU3EVN6G60C
GTIN: 0037332206800
3-Phase PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, the 18.7kW PDU3EVN6G60C provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with IEC 309 60A Blue (3P+E) input plug connects the 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the 0U PDU continues to perform at its best as connected equipment adds new features.

36 Outlets Dispense AC Power
During normal operation, 36 C13 outlets distribute AC power to connected equipment. Each 208/240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into six load banks, each protected by a 20A circuit breaker that trips if the bank’s connected load exceeds its maximum load rating. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 3-phase PDU with outlets facing the rear for better airflow or equipment access.

TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6G60C is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

2-Year Warranty
The PDU3EVN6G60C is backed by a 2-year warranty, ensuring reliability and performance.

Typical Applications
- Power a major data center with hundreds of server racks running mission-critical applications
- Monitor power loads from various computers, switches, servers and other networking equipment
- Distribute power to a computer network in a large commercial or industrial facility

Package Includes
- PDU3EVN6G60C 18.7kW 3-Phase Monitored PDU
- Built-in LX Platform interface
- Configuration cable
- (36) Plug-lock insert sleeves
- Rack-mounting hardware
- Spare mounting buttons
- PDUMVROTATEBRKT mounting bracket accessory
- Owner’s manual
3-Phase PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, the 18.7kW PDU3EVN6G60C provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with IEC 309 60A Blue (3P+E) input plug connects the 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the 0U PDU continues to perform at its best as connected equipment adds new features.

36 Outlets Dispense AC Power
During normal operation, 36 C13 outlets distribute AC power to connected equipment. Each 208/240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into six load banks, each protected by a 20A circuit breaker that trips if the bank’s connected load exceeds its maximum load rating. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 3-phase PDU with outlets facing the rear for better airflow or equipment access.

TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6G60C is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

2-Year Warranty
The PDU3EVN6G60C is backed by a 2-year warranty, ensuring reliability and performance.

Typical Applications
- Power a major data center with hundreds of server racks running mission-critical applications
- Monitor power loads from various computers, switches, servers and other networking equipment
- Distribute power to a computer network in a large commercial or industrial facility

Package Includes
- PDU3EVN6G60C 18.7kW 3-Phase Monitored PDU
- Built-in LX Platform interface
- Configuration cable
- (36) Plug-lock insert sleeves
- Rack-mounting hardware
- Spare mounting buttons
- PDUMVROTATEBRKT mounting bracket accessory
- Owner’s manual
Products specifications
Attribute nameAttribute value
Country of OriginTaiwan
Width2.17"
Depth2.49"
Height70"
Weight18.7 lbs
MountingVertical
Housing MaterialMetal
DisplayLCD
Cable Length70.9"
TypeThree-phase
Color-coded outletsYes
Compliance certificatesRoHS
Technical details
Product colorBlack, Gray
Sustainability certificatesRoHS
Packaging data
Package width9.65"
Package depth75.9"
Package height6.89"
Package weight25.4 lbs
Ports & interfaces
AC outlets quantity36 AC outlet(s)
AC outlet typesC13 coupler
Power plugIEC309
Design
CertificationUL 60950-1:2007 R10.14, CAN/CSA-C22.0 No 60950-1-07-A1:2009 A2:2014, NOM, TAA
PDU typesMonitored
Operational conditions
Operating temperature (T-T)32 - 122 °F
Storage temperature (T-T)-30 - 60 °C
Operating relative humidity (H-H)5 - 95 %
Operating altitude0 - 118110.2"
Power
Maximum current45 A
Maximum power18700 W
Nominal input voltage208; 240 V
Power protection featuresOverload
AC input frequency50 - 60 Hz
Features
Rack capacity0U
Other features
Nominal output voltage208; 240 V
Logistics data
Quantity per master (outer) case1 pc(s)
Security
Security algorithmsSNMP
Product tags
  • (82309)